Background

This randomized double-blind investigation was designed to study the placental transfer and neonatal effects of epidural sufentanil and fentanyl infused with bupivacaine for labor analgesia.

Methods

Healthy parturient women (n = 36) received epidural bupivacaine alone (group B) or with fentanyl (group B-F) or sufentanil (group B-S). Group B received a 12-ml bolus of 0.25% bupivacaine followed by a 10 ml/h infusion of 0.125% bupivacaine. Groups B-F and B-S received a 12-ml bolus of 0.125% bupivacaine with 75 micrograms fentanyl or 15 micrograms sufentanil, respectively, followed by 10 ml/h of 0.125% bupivacaine with fentanyl 1.5 micrograms/ml or sufentanil 0.25 micrograms/ml. Maternal venous (MV) and umbilical arterial (UA) and umbilical venous (UV) bupivacaine and opioid plasma concentrations were determined. Neonatal assessment included Apgar scores, umbilical cord blood gas analyses, and neurobehavioral testing at delivery and at 2 and 24 h of life using the Neurologic and Adaptive Capacity Score (NACS).

Results

The mean total dose of fentanyl was 136.6 +/- 13.1 micrograms (SEM), and of sufentanil, 23.8 +/- 1.8 micrograms. Although administered in a ratio of 5.7:1, fentanyl and sufentanil MV plasma concentrations were in the ratio of 27:1. UV/MV ratios were 0.37 for fentanyl and 0.81 for sufentanil. Fentanyl was detected in most UA samples, whereas sufentanil was present in only one sample. Neonatal condition was good and generally similar in all groups, with the exception of a lower NACS at 24 h in group B-F.

Conclusions

Although the degree of placental transfer of sufentanil appeared greater than that of fentanyl, lower MV sufentanil concentrations resulted in less fetal exposure to sufentanil. The lower NACS at 24 h in group B-F may reflect the continued presence of fentanyl in the neonate.

Methods: Healthy parturient women (n = 36) received epidural bupivacaine alone (group B) or with fentanyl (group B-F) or sufentanil (group B-S). Group B received a 12-ml bolus of 0.25% bupivacaine followed by a 10 ml/h infusion of 0.125% bupivacaine. Groups B-F and B-S received a 12-ml bolus of 0.125% bupivacaine with 75 micro gram fentanyl or 15 micro gram sufentanil, respectively, followed by 10 ml/h of 0.125% bupivacaine with fentanyl 1.5 micro gram/ml or sufentanil 0.25 micro gram/ml. Maternal venous (MV) and umbilical arterial (UA) and umbilical venous (UV) bupivacaine and opioid plasma concentrations were determined. Neonatal assessment included Apgar scores, umbilical cord blood gas analyses, and neurobehavioral testing at delivery and at 2 and 24 h of life using the Neurologic and Adaptive Capacity Score (NACS).

Results: The mean total dose of fentanyl was 136.6 plus/minus 13.1 micro gram (SEM), and of sufentanil, 23.8 plus/minus 1.8 micro gram. Although administered in a ratio of 5.7:1, fentanyl and sufentanil MV plasma concentrations were in the ratio of 27:1. UV/MV ratios were 0.37 for fentanyl and 0.81 for sufentanil. Fentanyl was detected in most UA samples, whereas sufentanil was present in only one sample. Neonatal condition was good and generally similar in all groups, with the exception of a lower NACS at 24 h in group B-F.

Conclusions: Although the degree of placental transfer of sufentanil appeared greater than that of fentanyl, lower MV sufentanil concentrations resulted in less fetal exposure to sufentanil. The lower NACS at 24 h in group B-F may reflect the continued presence of fentanyl in the neonate.

Key words: Analgesics, opioid: fentanyl; sufentanil. Anesthesia: obstetric. Anesthetic techniques: epidural.

EPIDURAL sufentanil and fentanyl are administered routinely in combination with bupivacaine to enhance analgesia during labor and delivery. The effects of epidural local anesthetic-opioid combinations on the parturient woman and the course of labor have been well documented. [1-4]However, there is little information regarding the accumulation of epidurally administered lipophilic opioids in the newborn and of possible adverse neonatal effects. This prospective, double-blind study was primarily designed to determine fetal and maternal plasma opioid concentrations after epidural sufentanil-bupivacaine and fentanyl-bupivacaine mixtures administered for labor and delivery and to assess neonatal neurobehavioral status. Information regarding analgesic efficacy and side effects also was obtained.

After approval of the study by the Human Subjects Committee, written informed consent was obtained from 36 healthy, term parturient women with uncomplicated pregnancies who requested epidural analgesia during labor. No subject had received any analgesic drugs before enrolling in the study. Patients were randomly assigned to receive plain bupivacaine (group B; n = 13), bupivacaine with fentanyl (group B-F; n = 14), or bupivacaine with sufentanil (group B-S; n = 9) in a double-blind manner. Group assignments were determined by a random numbers table and were sealed in sequentially numbered envelopes. Study solutions were freshly prepared by an anesthesiologist not involved in patient management or data collection. Epidural catheters were inserted via the L2-L3 or L3-L4 interspace by a standard technique. All patients received a 10-15 ml/kg intravenous infusion of lactated Ringer's solution before epidural block. An epinephrine test dose was not used. An initial 12-ml dose of study solution was administered incrementally through the epidural catheter over a 2-min period. This consisted of 12 ml 0.25% bupivacaine in group B, 12 ml 0.125% bupivacaine plus 6.25 micro gram/ml fentanyl (75 micro gram) in group B-F, and 12 ml 0.125% bupivacaine plus 1.25 micro gram/ml sufentanil (15 micro gram) in group B-S. Twenty minutes later, a continuous epidural infusion was started at 10 ml/h with group B receiving 0.125% bupivacaine, group B-F receiving 0.125% bupivacaine plus fentanyl 1.5 micro gram/ml and group B-S receiving 0.125% bupivacaine plus sufentanil 0.25 micro gram/ml. Breakthrough pain was treated with 5-ml boluses of 0.25% bupivacaine and by increasing the epidural infusion rate by 2 ml/h. The infusion rate was decreased by 2 ml/h increments if the sensory level was too high or motor block was considered excessive. The epidural infusion was continued throughout the second stage until delivery.

Data were obtained by an investigator blinded to the treatment. Analgesia was assessed by the patient on a 100-mm visual analog pain scale (VAPS), where 0 = no pain and 100 = worst possible pain. Pain scores, maternal blood pressure, heart rate and respiratory rate were recorded at 5-min intervals for the first 30 min, at 60 min, and then hourly until delivery. The following observations were recorded at the same times: the level of sensory blockade to pinprick; the degree of motor block according to a modified Bromage scale [5](full range of motion of hips, knees, and feet = 0, movement of knees and feet only = 1, movement of feet only = 2, and inability to move hips, knees, or feet = 3); nausea (rated 0-3, where 0 = none, 1 = mild, 2 = moderate, and 3 = vomiting); pruritus (rated as 0-3, where 0 = none, 1 = mild, 2 = moderate, and 3 = severe and requiring treatment), and somnolence (rated 0-3, where 0 = none, 1 = mild, 2 = moderate, and 3 = extreme). The patient rated the severity of each side effect. Urinary retention was considered present if the patient's bladder required catheterization. Analgesia at the time of delivery was ranked by the parturient woman on a scale of 0-3, where 0 = poor, 1 = fair, 2 = good, and 3 = excellent.

Neonatal evaluation included the time to sustained respiration, 1- and 5-min Apgar scores, and Neurologic and Adaptive Capacity Scores (NACS) [6]at 15 min, 2 h, and 24 h after birth. The NACS is designed to screen neonates for central nervous system depression and to differentiate central nervous system depression from asphyxia, trauma, or drug effect. The test has 20 criteria, divided into five categories: (1) adaptive capacity, (2) passive tone, (3) active tone, (4) primary reflexes, and (5) alertness. Neonates are given a rank of 0-2 for each neurobehavioral item where 0 = absent or grossly abnormal, 1 = mediocre or slightly normal, and 2 = vigorous or normal.

At the time of delivery, umbilical arterial (UA) and umbilical venous (UV) blood was obtained from a doubly clamped segment of umbilical cord for blood gas analyses (pH-blood gas analyzer model 178, Corning, Medfield, MA, with calculation of HCO3sup - values) and for determination of bupivacaine and opioid drug concentrations. Maternal blood was also obtained from an antecubital vein for the latter purpose. Blood was centrifuged and the plasma frozen for subsequent assay.

Plasma fentanyl and sufentanil concentrations were determined by gas chromatography-mass spectrometry using the modification described below of the method of Woestenborghs et al. [7]to increase sensitivity. This method consists of a multistep liquid-liquid extraction of plasma, concentration of the extract, and gas chromatography-mass spectrometry analysis of the extracts. An internal standard was used to correct for drug recovery throughout the extraction and analytical process. Selected ion monitoring was used to increase sensitivity. Our analytical limit of detection was 0.01 ng/ml for both fentanyl and sufentanil. We made several modifications to our standard sufentanil assay to achieve these levels. Samples were analyzed only after a rigorous cleaning of the mass spectrometer source and injector. We also injected one fifth of our sample extract using an increased injector pressure technique to transfer sample more fully onto the column. The interday coefficient of variation was 11.5% at 0.02 ng/ml. Plasma bupivacaine concentrations were measured with a gas chromatograph system (Hewlett-Packard) with a nitrogen phosphorus detector using an internal standard. The lower level of detection was 0.1 ng/ml and the interday coefficient of variation was 5.7% at 10 ng/ml bupivacaine.

Maternal and neonatal demographic data were analyzed by analysis of variance (ANOVA), chi-squared analysis, and Fisher's exact test as appropriate. Evaluation of nausea, pruritus and somnolence included calculating an hourly average side effect score for each symptom by dividing the sum of the hourly side effect rankings by the total hours the patient received epidural analgesia. The frequencies of side effects were compared by chi-squared analysis and hourly side effect scores were compared by the Kruskal-Wallis test. VAPS, as well as maternal hemodynamic and respiratory data, were analyzed by ANOVA and repeated measures ANOVA. Kruskal-Wallis test was used to compare Apgar scores and NACS. If significant overall differences among the groups were detected, intergroup comparisons were further investigated with Fisher's progressive least squares difference test or Dunnett's t test (after ANOVA), and the Mann-Whitney test with the Bonferroni correction for multiple comparisons (after the Kruskal-Wallis test). When chi-squared analysis indicated an overall difference among the groups, each pair of groups was then compared separately and the Bonferroni correction applied. Correlation between variables of continuous data was determined with Fisher's r-to-z correlation coefficient. Data are expressed as the mean plus/minus SEM except where otherwise noted. P < 0.05 was considered significant.

The groups were similar with respect to maternal age, height, and weight (Table 1). Group B-S had significantly more nulliparous women than did the other two groups. Patients in the three groups had similar pre-epidural VAPS, and all groups obtained satisfactory analgesia as demonstrated by a reduction in VAPS in the first 10 min after initiating epidural analgesia (Figure 1). Analgesia was better in group B-S at 20 min after initiation of epidural analgesia (P < 0.05 vs. group B-F; Figure 1) and at 2 h (P < 0.05 vs. group B-F); however, there were no differences at any other time until delivery. Analgesia in the three groups also was comparable in terms of the number of supplemental injections required for breakthrough pain, the total dose of bupivacaine administered, the duration of infusion (Table 2), and maternal assessment of analgesia at the time of delivery. All but one patient, who was in group B-F, rated analgesia for delivery as good or excellent. The mean total dose of sufentanil given was 23.8 plus/minus 1.8 micro gram (range 12.0-29.3 micro gram); the mean fentanyl dose was 136.6 plus/minus 13.1 micro gram (range 80.0-265.0 micro gram). The groups were similar with respect to the duration of labor and the mode of delivery (Table 2). No patient underwent cesarean delivery.

Table 1. Maternal Characteristics

Table 1. Maternal Characteristics
Table 1. Maternal Characteristics

Figure 1. Maternal assessment of epidural analgesia. All groups experienced a reduction in visual analog pain scale (VAPS) score, with better analgesia at 20 min and 2 h in the group receiving bupivacaine (BUP) with sufentanil. *P < 0.05, BUP with sufentanil vs. BUP with fentanyl).

Figure 1. Maternal assessment of epidural analgesia. All groups experienced a reduction in visual analog pain scale (VAPS) score, with better analgesia at 20 min and 2 h in the group receiving bupivacaine (BUP) with sufentanil. *P < 0.05, BUP with sufentanil vs. BUP with fentanyl).

Close modal

Table 2. Labor Characteristics and Assessment of Analgesia

Table 2. Labor Characteristics and Assessment of Analgesia
Table 2. Labor Characteristics and Assessment of Analgesia

The level of sensory blockade was similar for the three groups; upper levels ranged from T4-T10 (median T8). There were no significant changes in maternal mean arterial pressure, heart rate or respiratory rate after epidural analgesia in any of the groups, and no significant differences among the groups. The incidence of nausea was 38%, 15%, and 0% for groups B, B-F and B-S respectively, with no statistically significant differences in frequency (P = 0.12) or severity (P = 0.13). No patient experienced vomiting or required treatment. Pruritus occurred in 0% of group B, 50% of group B-F and 38% of group B-S patients (P = 0.04, group B vs. group B-F). The average hourly pruritus score was greatest in the B-F group (P = 0.012 vs. group B), although no patient required treatment for pruritus. The incidence and intensity of motor blockade were similar in all groups, with 47%, 35% and 33% of groups B, B-F, and B-S respectively, having a 1 or 2 modified Bromage score. Only one patient, who was in group B, developed a motor block score of 3.

Newborn characteristics and assessments are shown in Table 3. Apgar scores at 1 and 5 min and times to sustained respiration were satisfactory and similar in the three groups. Total NACS were similar among the groups at 15 min and 2 h after delivery. However, at 24 h, NACS in the B-F group were significantly lower than in groups B and B-S. When NACS component scores were compared, there were no statistically significant differences among the groups. The pattern of decreased NACS in the B-F group did not suggest perinatal asphyxia or birth trauma, which is often characterized by imbalances of extensor and flexor tone of the neck muscles or hypotonia of the lower extremities. [6]Umbilical cord blood gases were similar among the groups except for UV CO2tension (PCO2), which, although within normal limits, was significantly greater in group B-S infants (Table 4).

Table 3. Newborn Characteristics and Neonatal Assessment

Table 3. Newborn Characteristics and Neonatal Assessment
Table 3. Newborn Characteristics and Neonatal Assessment

Table 4. Umbilical Cord Blood Gases

Table 4. Umbilical Cord Blood Gases
Table 4. Umbilical Cord Blood Gases

Bupivacaine, sufentanil and fentanyl plasma concentrations are shown in Table 5and Table 6. Technical difficulties precluded obtaining sufficient UA blood for bupivacaine and opioid assays as well as for blood gas analyses in all cases. The mean UV bupivacaine concentration was significantly greater in group B-S than in the other two groups (Table 5). Sufentanil was detected in all but one maternal venous (MV) and all UV samples, but was undetectable in 4 of 5 of the UA samples obtained (Table 6). Fentanyl was detected in all MV, 12 of 13 UV, and 7 of 9 UA samples. The mean UV/MV ratios for each drug were obtained by calculating the ratio for each neonate and then averaging these values. There was a strong, statistically significant correlation between UV and MV drug concentrations for sufentanil (Figure 2) but not for fentanyl.

Table 5. Plasma Bupivacaine Concentration

Table 5. Plasma Bupivacaine Concentration
Table 5. Plasma Bupivacaine Concentration

Table 6. Maternal and Cord Plasma Opioid Concentration

Table 6. Maternal and Cord Plasma Opioid Concentration
Table 6. Maternal and Cord Plasma Opioid Concentration

Figure 2. The strong, significant correlation between maternal venous (MV) and umbilical venous (UV) sufentanil concentrations at the time of delivery. Fisher's r-to-z correlation coefficient was 0.952; P < 0.0001.

Figure 2. The strong, significant correlation between maternal venous (MV) and umbilical venous (UV) sufentanil concentrations at the time of delivery. Fisher's r-to-z correlation coefficient was 0.952; P < 0.0001.

Close modal

Several investigators have reported the effects of adding fentanyl or sufentanil to bupivacaine for labor analgesia. [1-4]In general, the addition of these lipophilic opioids to bupivacaine has improved labor analgesia and maternal satisfaction while allowing the administration of smaller quantifies of local anesthetic. [1,8,9]The resultant reduction in motor blockade has been accompanied in some studies by a decreased number of instrumental deliveries. [8,9]Although the benefits of this technique have been well documented for the parturient woman, the effect of epidural opioids on the neonate are not as well understood. Although clinically significant neonatal depression appears rare after maternal epidural opioid administration, [2-4]the potential for this complication certainly exists. In one study, [10]50-80-micro gram doses of epidural sufentanil given during cesarean delivery caused minor neonatal depression, and epidural fentanyl may have caused respiratory depression in two infants in another cesarean study. [11]Carrie et al. [12]also described respiratory depression in one infant when relatively large doses of epidural fentanyl were used without local anesthetics to provide labor analgesia. In all of these studies large doses of opioids were administered or an opioid bolus was given shortly before delivery. The current investigation was designed to evaluate the effects of fentanyl and sufentanil as they are used in current obstetric anesthesia practice: as a modest bolus dose followed by a low-dose infusion in combination with dilute bupivacaine.

We selected opioid concentrations for this study based on an approximately five- to sixfold relative potency of sufentanil to fentanyl when administered parenterally, [13]although Coda et al. [14]recently concluded that when given epidurally their relative potency may be closer to 3:1. Consideration also was given to limiting the total epidural sufentanil dose to the 30 micro gram previously shown to be safe for newborns. [9]The greater bupivacaine concentration in the bolus in group B was selected to ensure adequate onset of analgesia.

In this study we found significant placental transfer of sufentanil and fentanyl after epidural administration during labor; sufentanil transfer appeared greater than that of fentanyl. The larger UV/MV ratio for sufentanil as compared with fentanyl (0.81 vs. 0.37; P = 0.003) may reflect the greater lipid solubility of sufentanil relative to that of fentanyl, as determined by their octanol: buffer distribution coefficients (fentanyl 955 and sufentanil 1,737). [15]The degree of placental transfer of sufentanil in this study is greater than that reported by others. Kick et al.,* for example, were unable to detect sufentanil in neonatal plasma after epidural administration of 10-30 micro gram given for labor analgesia. The plasma UV/MV ratio for sufentanil of 0.33 reported by Palot et al.,** also was much less than the 0.81 value we obtained. Steinberg et al. [16]failed to detect sufentanil in 14 (37%) of 38 UV samples after administration of sufentanil by an intermittent bolus technique for labor analgesia, whereas in the current study sufentanil was detected in all of the UV plasma samples obtained. These differences can be explained by the greater degree of sensitivity of our sufentanil assay, which had a lower limit of detection of 0.01 ng/ml compared with 0.02-0.05 ng/ml in the other studies cited. The UV/MV ratio for sufentanil in our study is similar to that reported by Vertommen et al. [17]when the opioid was administered epidurally in larger doses with bupivacaine for cesarean section. The significant correlation between MV and UV sufentanil concentrations in this study may reflect rapid placental diffusion of sufentanil as a result of its lipophilicity. There was no correlation between sufentanil UV concentrations and other factors such as total sufentanil dose or UV pH.

Highly lipophilic drugs have generally been considered to undergo more rapid placental [18]and dural [19]transfer than less lipophilic agents. However, some studies have shown that tissue permeability of spinal meninges [20]or rabbit cornea [21]has a biphasic relation; extremely hydrophilic and hydrophobic drugs had lower permeability coefficients than drugs of intermediate hydrophobicity. This may relate to layers of varying lipid and water content within these membranes resulting in rate-limiting steps with drugs at either extreme of solubility. [20,22]Whether or not this is applicable to placental transfer is unclear. In two in vitro studies of fentanyl [23]and sufentanil [24]in a perfused human placenta model, Zakowski et al. demonstrated rapid transfer of both fentanyl and sufentanil. Maternal-to-fetal clearance for fentanyl was somewhat greater than that for sufentanil; however, fetal-to-maternal clearance was greater with sufentanil, which also was sequestered in larger amounts within the placenta. [24]In vivo, factors other than intrinsic tissue permeability assume importance. This is particularly true for lipophilic drugs, the transfer of which is strongly influenced by three factors: placental blood flow, which helps to maintain the concentration gradient; protein binding on either side of the placenta, which affects the gradient of the diffusible unbound drug; and the area available for drug diffusion. [25].

Studies such as the current one are limited in that the UV/MV ratio describes only the relative concentrations of drug in the blood at one point in time (delivery), which may not reflect the total amount of the drug in the neonate. Highly lipophilic drugs may well be sequestered in the neonatal brain or other tissues. Indeed, the absence of sufentanil in most of the UA samples in the current study indicates neonatal tissue uptake of sufentanil and incomplete drug redistribution in the fetus at the time of delivery. We believe that clinically significant concentrations of sufentanil were unlikely to have been present in the neonatal brain at birth, given the vigorous behavior of these infants. However, in view of the degree of placental transfer of epidural sufentanil, it is conceivable that very large doses might result in neonatal depression. [10].

One finding that is not easily explained is the greater UV P sub CO2in group B-S compared with the other groups. This could reflect maternal opioid respiratory depression acutely increasing maternal arterial PCO2with a resultant increase in UV PCO2, or decreased placental perfusion. Although there was no clinical evidence of respiratory depression in the mothers, maternal blood gas analyses were not available to confirm this. Extensive clinical experience with epidural sufentanil given during labor suggests that maternal respiratory depression is an uncommon problem. The greater UV bupivacaine concentrations in group B-S also are hard to explain, as total cumulative dosages of bupivacaine were similar in the three groups. It is tempting to relate the increased UV bupivacaine concentration in group B-S to the greater UV PCO2in this group. Although UV pH was not statistically different among the groups and all values were within the normal range, the mean UV pH was lower in group B-S than in groups B-F and B. A mild respiratory acidosis and slightly elevated UV pH are common in healthy newborns and may result from numerous factors including maternal hypotension or aortocaval compression, a prolonged second stage with vigorous maternal expulsive efforts, [26,27]decreased placental perfusion, and umbilical cord compression. Decreased fetal pH and acidosis can result in greater bupivacaine concentrations as a result of several mechanisms, including ion trapping (an increase in the un-ionized drug fraction on the fetal side of the placenta, which decreases fetal-maternal bupivacaine transfer) [28]; increased maternal-fetal drug clearance due to an increased gradient of un-ionized drug [29]; changes in protein binding, which may affect the gradient of un-ionized drug; and changes in fetal drug clearance or tissue distribution. In a study in pregnant rabbits, Gaylard et al. [25]also found that bupivacaine underwent increased placental transfer during a period of maternal hypoperfusion, perhaps because of mobilization of drug stored within the placenta. Thus, although the difference in UV pH between the B-S and other groups was small, in conjunction with factors that affect placental perfusion (e.g., maternal aortocaval compression) it may have influenced bupivacaine transfer. An alternative and more likely explanation is that the greater UV bupivacaine concentration in group B-S merely reflected the somewhat greater MV value in this group. Despite small differences among the groups, bupivacaine concentrations in group B-S neonates were low and not a cause for concern, particularly because bupivacaine is free of neurobehavioral effects. [30]Newer techniques using more dilute bupivacaine infusions should result in even lower neonatal concentrations.

Although substantial placental transfer of both opioids occurred, absolute levels were low and there were no differences in Apgar scores, time to sustained respiration, or NACS at the time of delivery when compared with the control group. Although neonates in all groups had comparable NACS at 2 h, the NACS at 24 h in group B-F were significantly lower than those in the other groups. The composite scores for groups B-S and B newborns reflect the usual improvement seen over the first 24 h, whereas those for group B-F newborns did not improve during this period. Although the numbers in this study are small, they should be sufficient to detect a statistically significant difference in NACS of 1.5 points among the groups with a power of 0.8 and 95% confidence. Helbo-Hansen et al. [31]also reported lower NACS scores in certain categories at 2 and 24 h in newborns delivered by cesarean section using epidural anesthesia with fentanyl (50-100 micro gram) and bupivacaine. The lower NACS at 24 h in group B-F may relate to a longer elimination half-life for fentanyl resulting in a persistent, mild depressant effect. Pharmacokinetic studies of fentanyl in newborns have shown that clearance is low in the early neonatal period, perhaps as a result of immature liver enzyme systems. [32]As newborn blood samples were not obtained in the current study, it was not possible to correlate opioid plasma concentrations at 24 h with neurobehavioral scores.

Why were neurobehavioral effects greater with fentanyl when UV/MV drug ratios were greater with sufentanil? This apparent paradox can partly be explained by differences in maternal uptake of the opioids. Although we administered fentanyl and sufentanil in a ratio of 5.7:1, the ratio of fentanyl to sufentanil in MV samples was 27:1, an almost fivefold increase in the relative concentration of fentanyl to sufentanil. This probably reflects greater maternal uptake of sufentanil than of fentanyl, resulting in relatively less neonatal exposure to sufentanil. UV sufentanil levels were extremely low, with a ratio of fentanyl to sufentanil in UV samples of 11:1. Restated simply, the amount of sufentanil that crosses the placenta is insignificant because, relative to the doses given, sufentanil concentrations perfusing the placenta are approximately five-fold lower than those of fentanyl. In addition, greater absorption of sufentanil than of fentanyl by the placenta, and greater fetal-to-maternal clearance of sufentanil [23,24]may further explain the lower neonatal concentrations and lack of neurobehavioral effects with sufentanil. Despite our findings, we do not believe that the differences in NACS indicate neurobehavioral depression with fentanyl that is of clinical concern, particularly considering that seventy percent of group B-F newborns had a NACS greater than 35 at 24 h. To date, no adverse long term effects have been associated with transient drug-related neurobehavioral depression. [33,34]Despite this, the American Academy of Pediatrics Committee on Drugs has recommended that, during labor, drugs be used that have the least effect on the neonate, as determined by neurobehavioral testing. [35]Our findings with sufentanil confirm those of others [4],* who have similarly found no effect on neonatal neurobehavior with doses less than 30 micro gram in this circumstance.

In summary, the anesthetic techniques used in this study all provided adequate analgesia for labor and delivery with no severe side effects in any of the groups. However, given the small number of patients, it is not possible to draw firm conclusions regarding differences in efficacy or side effects with these three regimens. Placental transfer of both sufentanil and fentanyl occurs when these drugs are administered epidurally for labor analgesia. Although placental transfer of sufentanil appears to be greater than that of fentanyl and is strongly correlated with maternal concentrations, significant maternal sufentanil uptake may considerably reduce neonatal opioid exposure. Fentanyl administration was associated with lower neurobehavioral test scores at 24 h of life, although none of the newborns had clinically significant depression. Although both drugs are acceptable for use with epidural bupivacaine during labor, the reduced neonatal opioid exposure with sufentanil suggests that it may have some advantages over fentanyl.

The authors thank Barbara Coda, M.D. for her assistance with information regarding the fentanyl and sufentanil assays performed by the late Harlan Hill.

* Kick O, Vertommen JD, Van Aken H, Gryseels J: Sufentanil: Maternal and neonatal plasma levels after epidural administration during labor and delivery (abstract). ANESTHESIOLOGY 75:A837, 1991.

** Palot M, Visseaux H, Botmans C, Levron JC, Lemoing JP: Placental transfer and neonatal distribution of fentanyl, alfentanil, and sufentanil after continuous epidural administration for labor (abstract). ANESTHESIOLOGY 77:A991, 1992.

1.
Chestnut DH, Owen CL, Bates JN, Ostman LG, Choi WW, Geiger MW: Continuous infusion epidural analgesia during labor: A randomized, double-blind comparison of 0.0625% bupivacaine/0.0002% fentanyl versus 0.125% bupivacaine. ANESTHESIOLOGY 68:754-759, 1988.
2.
Cohen SE, Tan S, Albright GA, Halpern J: Epidural fentanyl/ bupivacaine mixtures for obstetric analgesia. ANESTHESIOLOGY 67:403-407, 1987.
3.
Phillips GH: Combined epidural sufentanil and bupivacaine for labor analgesia. Reg Anesth 12:165-168, 1987.
4.
Russell R, Reynolds F: Epidural infusions for nulliparous women in labor. Anaesthesia 48:856-861, 1993.
5.
Bromage PR: A comparison of the hydrochloride and carbon dioxide salts of lidocaine and prilocaine in epidural analgesia. Acta Anaesthesiol Scand Suppl 16:55-69, 1965.
6.
Amiel-Tison C, Barrier G, Shnider SM, Levinson G, Hughes SC, Stefani SJ: A new neurologic and adaptive capacity scoring system for evaluating obstetric medications in full-term newborns. ANESTHESIOLOGY 56:340-350, 1982.
7.
Woestenborghs RJ, Stanski DR, Scott JC, Heykants JJ: Assay methods for fentanyl in serum: Gas-liquid chromatography versus radioimmunoassay. ANESTHESIOLOGY 67:85-90, 1987.
8.
Murphy JD, Henderson K, Bowden MI, Lewis M, Cooper GM: Bupivacaine versus bupivacaine plus fentanyl for epidural analgesia: Effect on maternal satisfaction. Br Med J 302:564-567, 1991.
9.
Vertommen JD, Vandermeulen E, VanAken H, Vaes L, Soetens M, Van Steenberge A, Mourisse P, Willaert J, Noorduin H, Devlieger H, Van Assche AF: The effects of the addition of sufentanil to 0.125% bupivacaine on the quality of analgesia during labor and the incidence of instrumental deliveries. ANESTHESIOLOGY 74:809-814, 1991.
10.
Capogna G, Celleno D, Tomassetti M: Maternal analgesia and neonatal effects of epidural sufentanil for cesarean section. Reg Anesth 14:282-287, 1989.
11.
Noble OW, Morrison LM, Bruckway MS, McClure JH: Adrenaline, fentanyl or adrenaline and fentanyl as adjuncts to bupivacaine for anaesthesia in elective caesarean section. Br J Anaesth 66:645-650, 1991.
12.
Carrie LES, O'Sullivan GM, Seegobin R: Epidural fentanyl in labour. Anaesthesia 36:965-969, 1981.
13.
Bailey PL, Stanley TH: Narcotic intravenous anesthetics, Anesthesia. 3rd edition. Edited by Miller RD. New York, Churchill Livingstone, 1990, pp 336-337.
14.
Coda BA, Cleveland Brown M, Schaffer R, Donaldson G, Jacobson R, Hautman B, Shen DD: Pharmacology of epidural fentanyl, alfentanil, and sufentanil in volunteers. ANESTHESIOLOGY 81:1149-1161, 1994.
15.
Mather LE: Clinical pharmacokinetics of fentanyl and its newer derivatives. Clin Pharmacokinet 8:422-426, 1983.
16.
Steinberg RB, Dunn S, Dixon D, Rehm K, Pastides H, Hu X: Comparison of sufentanil, bupivacaine, and their combination for epidural analgesia in obstetrics. Reg Anesth 17:131-138, 1992.
17.
Vertommen JD, VanAken H, Vandermeulen E, Vangerven M, Devlieger H, Van Assche A, Shnider SM: Maternal and neonatal effects of adding epidural sufentanil to 0.5% bupivacaine for cesarean delivery. J Clin Anesth 3:371-376, 1991.
18.
Finster M, Ralston DH, Pederson H: Perinatal pharmacology, Anesthesia for Obstetrics. Edited by Shnider SM, Levinson G. Baltimore, Williams and Wilkins, 1993, pp 71-79.
19.
Cousins MJ, Cherry DA, Gourlay GK: Acute and chronic pain: Use of spinal opiates, Neural Blockade in Clinical Anesthesia and Management of Pain. 2nd edition. Edited by Cousins MJ, Bridenbaugh PO. Philadelphia, JB Lippincot, 1988, pp 955-1029.
20.
Bernards CM, Hill HF: Physical and chemical properties of drug molecules governing their diffusion through the spinal meninges. ANESTHESIOLOGY 77:750-756, 1992.
21.
Schoenwald RD, Ward RL: Relationship between steroid permeability across excised rabbit cornea and octanol-water partition coefficients. J Pharm Sci 67:786-788, 1978.
22.
Moore RA, Bullingham RES, McQuay HJ, Hand CW, Aspel JB, Allen MC, Thomas D: Dural permeability to narcotics: In vitro determination and application to extradural administration. Br J Anaesth 54:1117-1128, 1982.
23.
Zakowski M, Schlesinger J, Dumbroff S, Grant G, Turndorf H: In vitro human placental uptake and transfer of fentanyl (abstract). ANESTHESIOLOGY 79:A1006, 1993.
24.
Zakowski MI, Grant GJ, Turndorf H: Uptake and transfer of sufentanil in human placenta during in vitro perfusion (abstract). Anesth Analg 80:S577, 1995.
25.
Gaylard DG, Carson RJ, Reynolds F: Effect of umbilical perfusate pH and controlled maternal hypotension on placental drug transfer in the rabbit. Anesth Analg 71:42-48, 1990.
26.
Pearson JF, Davies P: The effect of continuous lumbar epidural analgesia upon fetal acid-base status during the second stage of labour. Journal of Obstetrics and Gynaecology of the British Commonwealth 81:975-979, 1974.
27.
Pearson JF, Davies P: The effect of continuous lumbar epidural analgesia on maternal acid-base balance and arterial lactate concentration during the second stage of labour. Journal of Obstetrics and Gynaecology of the British Commonwealth 80:225-229, 1973.
28.
Pickering B, Biehl D, Meatherall R: The effect of foetal acidosis on bupivacaine levels in utero. Can Anaesth Soc J 28:544-549, 1981.
29.
Johnson RF, Herman N, Arney TL, Gonzales H, Johnson HV, Downing JW: Bupivacaine transfer across the human term placenta: A study using the dual perfused human placenta model. ANESTHESIOLOGY 82:459-468, 1995.
30.
Scanlon JW, Ostheimer GW, Lurie OA, Brown WU, Weiss JB, Alper MH: Neurobehavioral responses and drug concentrations in newborns after maternal epidural anesthesia with bupivacaine. ANESTHESIOLOGY 45:400-405, 1976.
31.
Helbo-Hansen HS, Bang U, Lindohlm P, Klitgard NA: Neonatal effects of adding fentanyl 0.5% bupivacaine for caesarean section. International Journal of Obstetric Anesthesia 2:27-33, 1993.
32.
Gauntlett IS, Fisher DM, Hertzka RE, Kuhls E, Spellman MJ, Rudolph C: Pharmacokinetics of fentanyl in neonatal humans and lambs: Effects of age. ANESTHESIOLOGY 69:683-687, 1988.
33.
Ounsted M, Scott A, Moar V: Delivery and development: To what extent can one associate cause and effect? J R Soc Med 73:786-792, 1980.
34.
Ounsted M: Pain relief during childbirth and development at 4 years. J R Soc Med 74:629-630, 1981.
35.
American Academy of Pediatrics Committee on Drugs: Effect of medication during labor and delivery on infant outcome. Pediatrics 62:402-403, 1978.