Abstract
The objective of the study was to determine the effect of the use of cuffs with different bladder sizes on the outcome of blood pressure (BP) measurements. Two sizes of bladders previously in common use in the study location (13 × 23 cm and 16 × 23 cm) were compared with the current size (13 × 36 cm). A fully randomised, experimental study was carried out on a study population comprising 130 subjects (61 men, 69 women, aged between 22 and 70, mean 49) who were not undergoing special treatment for cardiovascular disease or hypertension at that time. The mean arm circumference was 32.9 cm (range 25–40 cm). BP measurements were carried out by one person, using a Hawksley random zero sphygmomanometer under standardised conditions. With the smallest bladder (13 × 23 cm) the highest systolic and diastolic BP was measured (mean SBP 127.2 mean DBP 77.0 mm Hg), followed by the bladder of 13 × 36 cm (125.1 resp. 75.4 mm Hg). The lowest BP was measured with the bladder of 16 × 23 cm (123.7 resp. 74.4 mm Hg). Differences between bladders were significant for all arm circumferences. Over the entire range of arm circumferences in the present study there is a small systematic difference in the BP measurements taken by the various bladder sizes. For individual readings the difference is less marked, in comparison to other factors that can affect BP measurements. However, in longitudinal studies a systematic error in BP can occur when measurements are made with different bladders during the study.
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 12 digital issues and online access to articles
$119.00 per year
only $9.92 per issue
Rent or buy this article
Prices vary by article type
from$1.95
to$39.95
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Bakx, C., Oerlemans, G., van den Hoogen, H. et al. The influence of cuff size on blood pressure measurement. J Hum Hypertens 11, 439–445 (1997). https://doi.org/10.1038/sj.jhh.1000470
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1038/sj.jhh.1000470
Keywords
This article is cited by
-
Unsafe health and safety: sphygmomanometer cuffs are not interchangeable
Journal of Human Hypertension (2013)
-
Variation in recorded blood pressure terminal digit bias in general practice
Journal of Human Hypertension (2008)
-
Tables for the selection of correct blood pressure cuff size based on self-reported height and weight and estimating equations for mid-arm circumference: data from the US National Health and Nutrition Examination Survey
Journal of Human Hypertension (2006)
-
US demographic trends in mid-arm circumference and recommended blood pressure cuffs: 1988–2002
Journal of Human Hypertension (2005)
-
Arterial hypertension in Poland in 2002
Journal of Human Hypertension (2004)