Table 4.

Descriptive Findings from the FIT Kit Specimen Adequacy Analysis (N = 66)

OC-Light® (N = 12)Hemosure® iFOB Test (N = 13)InSure® FIT™ (N = 7)QuickVue® (N = 11)OneStep+ (N = 12)Hemoccult® ICT (N = 11)
Packaged correctly7 (58)8 (62)7 (100)8 (73)12 (100)10 (91)
    In mailer (Y)11 (92)11 (85)7 (100)10 (91)12 (100)10 (91)
    In bio bag (Y)8 (67)11 (85)N/A11 (100)N/AN/A
    With pad (C)7 (58)8 (62)N/A9 (82)N/AN/A
Labeled correctly8 (67)5 (38)6 (86)5 (45)8 (67)7 (64)
    Label (Y)7 (58)5 (38)5 (71)5 (45)7 (58)7 (64)
    Different days (Y)N/AN/A4 (57)N/A4 (33)5 (45)
    Collection date (Y)8 (67)5 (38)6 (86)4 (36)7 (58)7 (64)
Sampled correctly10 (83)12 (92)6 (86)11 (100)11 (92)7 (64)
    Color of liquid (T/B)10 (83)12 (92)N/A11 (100)N/AN/A
    Returned all cardsN/AN/A7 (100)*N/A12 (100)*9 (82)
    Sample on all cardsN/AN/A7 (100)N/A11 (92)8 (73)
    Specimen appearanceN/AN/A7 (100)N/A12 (100)10 (91)
    Coverage (>50%)N/AN/A6 (86)N/A11 (92)7 (64)
    ClosedN/AN/A7 (100)N/A12 (100)10 (91)
  • B, brown; C, correct; T, tan; Y, yes.

  • * 1 card total.

  • 3 cards total.