Skip to main content

Main menu

  • Home
  • Articles
    • Current Issue
    • COVID-19
    • Ahead of Print
    • Archives
    • Abstracts In Press
    • Editors' Blog
    • Email Alerts
  • Info For
    • Authors
    • Reviewers
    • Subscribers
    • Advertisers
  • SUBMIT
    • Manuscript
    • Peer Review
  • About
    • The JABFM
    • Editorial Board
    • Indexing
  • Classifieds
  • More
    • Email Alerts
    • Feedback
    • ABFM News
    • Folders
    • Help
  • Other Publications
    • abfm

User menu

Search

  • Advanced search
American Board of Family Medicine
  • Other Publications
    • abfm
American Board of Family Medicine

American Board of Family Medicine

Advanced Search

  • Home
  • Articles
    • Current Issue
    • COVID-19
    • Ahead of Print
    • Archives
    • Abstracts In Press
    • Editors' Blog
    • Email Alerts
  • Info For
    • Authors
    • Reviewers
    • Subscribers
    • Advertisers
  • SUBMIT
    • Manuscript
    • Peer Review
  • About
    • The JABFM
    • Editorial Board
    • Indexing
  • Classifieds
  • More
    • Email Alerts
    • Feedback
    • ABFM News
    • Folders
    • Help
  • JABFM On Twitter
  • JABFM On YouTube
  • JABFM On Facebook
OtherResearch Letter

Comparison of Point of Care and Laboratory HbA1c Analysis: A MetroNet Study

Kendra L. Schwartz, Joseph Monsur, Adnan Hammad, Monina G. Bartoces and Anne Victoria Neale
The Journal of the American Board of Family Medicine July 2009, 22 (4) 461-463; DOI: https://doi.org/10.3122/jabfm.2009.04.090057
Kendra L. Schwartz
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Joseph Monsur
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Adnan Hammad
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Monina G. Bartoces
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Anne Victoria Neale
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

Background: Evaluating new technology in clinical practice is an important component of translating research into practice. We considered the feasibility of using a Clinical Laboratory Improvement Amendments (CLIA)-waived point of care (POC) glycohemoglobin (HbA1c) methodology in busy family medicine centers by comparing the results of POC HbA1c and laboratory analysis results.

Methods: Recruited from 5 MetroNet practices, the participants were adult diabetic patients having blood samples drawn for laboratory analysis of HbA1c. Each agreed to provide a capillary blood sample for POC testing.

Results: With data on 99 paired samples, the POC method yielded a mean HbA1c of 7.38%, which was equivalent to the mean of 7.53% produced with all combined standard laboratory analyses. The Pearson correlation between POC and the laboratory analysis test results was 0.884 (P < .001). POC test sensitivity was 81.8% and specificity was 93.2%. Eighteen percent of patients with an HbA1c ≥7% by laboratory analysis were not identified as such by the POC test.

Conclusions: Before adopting a POC methodology, practices are encouraged to review its feasibility in the context of the office routine, and also to conduct periodic comparisons of the accuracy of POC test results compared with those from laboratory analysis.

View Full Text
PreviousNext
Back to top

In this issue

The Journal of the American Board of Family Medicine: 22 (4)
The Journal of the American Board of Family Medicine
Vol. 22, Issue 4
July-August 2009
  • Table of Contents
  • Table of Contents (PDF)
  • Cover (PDF)
  • Index by author
  • Back Matter (PDF)
  • Front Matter (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Board of Family Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Comparison of Point of Care and Laboratory HbA1c Analysis: A MetroNet Study
(Your Name) has sent you a message from American Board of Family Medicine
(Your Name) thought you would like to see the American Board of Family Medicine web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
9 + 2 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Comparison of Point of Care and Laboratory HbA1c Analysis: A MetroNet Study
Kendra L. Schwartz, Joseph Monsur, Adnan Hammad, Monina G. Bartoces, Anne Victoria Neale
The Journal of the American Board of Family Medicine Jul 2009, 22 (4) 461-463; DOI: 10.3122/jabfm.2009.04.090057

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Comparison of Point of Care and Laboratory HbA1c Analysis: A MetroNet Study
Kendra L. Schwartz, Joseph Monsur, Adnan Hammad, Monina G. Bartoces, Anne Victoria Neale
The Journal of the American Board of Family Medicine Jul 2009, 22 (4) 461-463; DOI: 10.3122/jabfm.2009.04.090057
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Methods
    • Results
    • Discussion
    • Notes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • The Most Frequently Read Practice-based Research (PBR) Articles in the Journal of the American Board of Family Medicine (JABFM)
  • Few Point-of-Care Hemoglobin A1c Assay Methods Meet Clinical Needs
  • Google Scholar

More in this TOC Section

  • Perspectives on Dermoscopy in the Primary Care Setting
  • A Proposed Opioid Tapering Tool
  • Primary Care Clinician Decision-Making Around Surveillance Colonoscopies in Older Adults with Prior Adenomas
Show more Research Letter

Similar Articles

Navigate

  • Home
  • Current Issue
  • Past Issues

Authors & Reviewers

  • Info For Authors
  • Info For Reviewers
  • Submit A Manuscript/Review

Other Services

  • Get Email Alerts
  • Classifieds
  • Reprints and Permissions

Other Resources

  • Forms
  • Contact Us

© 2021 American Board of Family Medicine

Powered by HighWire